Introduction
Jump performance is widely assessed in sports science and rehabilitation to characterize lower-limb function, neuromuscular performance, and fatigue. Force plates provide direct measurements of vertical ground-reaction force (vGRF) and are commonly used to quantify variables such as force, power, impulse, and landing force. They can also be used to estimate jump height using methods such as flight time or impulse–momentum calculations (
1-
3). However, force plates are expensive, non-portable, and generally limited to laboratory settings, which can restrict their use for routine assessment in field and clinical environments.
Inertial measurement units (IMUs) and smartphone-based sensors offer more portable and accessible options for assessing jump performance. IMUs typically combine accelerometers with gyroscopes and may also include magnetometers, whereas smartphone applications use built-in sensors to estimate outcomes such as flight time and jump height (
4-
12). Despite their accessibility, the validity of measurements derived from IMUs and smartphones remains an important concern. Previous validation studies have reported variable performance depending on the jump task, sensor location, participant characteristics, and processing methods (
4-
8,
10,
12). Although accelerometer-based approaches have also been examined during jumping and landing tasks, most have focused on variables such as peak acceleration, peak velocity, peak GRF, and jump height (
13-
15). Fewer studies have evaluated several kinetic outcomes simultaneously, including peak concentric force, peak concentric power, and maximum landing force, across both countermovement and drop jumps within the same sample and analytical framework. Evaluating multiple outcomes across tasks can help clarify whether device performance is outcome- and task-specific. Different jump tasks impose distinct mechanical demands and provide complementary information about lower-limb function (
16,
17). While the countermovement jump (CMJ) is widely used due to its simplicity and familiarity, the drop jump (DJ), which includes two landing phases, with the first phase initiating a subsequent jump, introduces a reactive component that places greater demands on stretch-shortening cycle efficiency and landing mechanics. Assessing both CMJ and DJ provides a more comprehensive understanding of neuromuscular control, particularly in athletic and rehabilitative contexts where explosive strength and impact absorption are critical.
The present study aimed to evaluate the concurrent validity of variables derived from an IMU and a smartphone by comparing them with gold standard force plate measurements across both CMJ and DJ tasks. To provide a comprehensive validation, absolute agreement was assessed using Bland–Altman bias and limits of agreement (LoA), while relative validity was examined through intraclass correlation coefficients (ICC) and Pearson’s correlation. The outcomes included jump height and three kinetic variables including peak concentric force, reflecting maximal force producing capacity during propulsion; peak concentric power, representing the combined contribution of force and velocity to explosive output; and maximum landing force, which provides insight into shock absorption and lower limb load management. Furthermore, this study incorporates the more mechanically demanding DJ, a task that has been less frequently evaluated in prior validation work but is critical for understanding sensor performance during high-demanding movements. We hypothesized that: (
1) the IMU would demonstrate better agreement with the force plate than the smartphone across all variables. Acceptable validity was defined a priori as ICC ≥ 0.75 and SEE < 10% of the measurement range, based on established reliability frameworks (
22,
23). Limits of agreement exceeding approximately 15–20% of the mean value were considered too wide for individual-level decision-making. These criteria were specified before data analysis and were not modified post hoc.
Methods
Participants
Twenty‑four physically active females voluntarily participated in this study. A supplementary sample-size precision assessment was conducted using the method described by Bonett (2002) for estimating intraclass correlation coefficients (ICCs). Assuming a planning ICC of 0.90, two measurement methods per comparison, a 95% confidence level, and a target confidence interval width of 0.20, Bonett's results indicate a requirement of approximately 21 participants for the corresponding two-way ICC models. The present study included 24 participants. This assessment was intended to contextualize the precision of ICC estimation rather than to establish statistical power for all agreement outcomes. Because the required sample size depends on the underlying ICC and the specified precision, this calculation should not be interpreted as demonstrating adequate precision for all device comparisons or biomechanical variables. The sample size was chosen according to previous studies on this filed (
18-
20). Inclusion criteria were: (
1) female adults aged 18–35 years with a normal BMI (18.5–24.9 kg/m²); (
2) not professional athletes, but physically active, with engagement in regular physical activity (≥3 aerobic exercise sessions per week) and a Tegner activity level of 5–6; and (
3) prior experience performing vertical jump tasks, including both the CMJ and the DJ, as self-reported by participants who performed these jumps in the gym or as a warm-up before recreational play. Exclusion criteria were: (
1) any history of permanent orthopedic conditions or previous fractures of the lower limbs or lumbar spine, verified through screening by the primary researcher (a physiotherapist with MSclevel training) (
2) any lower‑limb musculoskeletal injury within the past six months, defined as pain, swelling, or functional limitation requiring modification of activity; (
3) and diagnosed neurological or balance disorders. Eligibility was verified through a two-stage process. First, participants completed a standardised self-report screening questionnaire covering aerobic activity frequency, prior jumping experience, injury history, and neurological or balance disorders. Jumping experience was confirmed verbally, with participants required to describe the specific context in which they had performed the jumps; those unable to do so were excluded. Second, all participants underwent a focused clinical screening examination performed by the primary investigator (a physiotherapist with MSc-level training), which included history-taking for orthopedic, fracture, and neurological or balance conditions, and a brief lower-limb and lumbar spine examination (observation, active range of motion, and provocation tests where indicated). Thus, exclusion criteria were verified by combined self-report and clinical examination, not by self-report alone. The study protocol was approved by the Institutional Ethics Committee of Tarbiat Modares University (approval code: IR.MODARES.REC.1400.107) and conducted in accordance with the Declaration of Helsinki. Written informed consent was obtained from all participants prior to data collection.
Study Design
This study aimed to compare CMJ and DJ performance metrics obtained from three measurement systems: a laboratory-grade force plate, a wearable IMU, and a smartphone. Each participant completed a standardized dynamic warm-up consisting of 5 min of stationary cycling, followed by 10 repetitions each of walking lunges, reverse lunges, straight-leg kicks, high knees, and butt kicks, and then completed three valid trials of both the CMJ and the DJ. The valid trial was as The CMJ involved a rapid downward movement (eccentric phase) immediately followed by an explosive upward jump (concentric phase), utilizing the stretch-shortening cycle. Participants were instructed to jump as fast and as high as possible. A trial was considered valid if the hands remained on the waist throughout the jump, no additional stop occurred in knee flexion before the jump, the participant did not walk or step after landing, and the participant's attention was not distracted. The DJ task involved stepping off a 20-cm box and immediately initiating a reactive vertical jump upon ground contact. The participant moved one foot forward and allowed the body to fall from the box without actively pushing off with the legs, so that the drop was initiated by gravity with minimal upward or downward propulsion at departure. A 20-cm height was selected primarily based on our pilot testing, in which it was well tolerated by participants; greater heights were associated with pain on landing, cautious landing mechanics, and difficulty performing subsequent jumps. Higher drop heights were therefore avoided, as they resulted in altered landing mechanics and excessive impact forces that caused discomfort in this population. A DJ trial was considered valid under the same criteria applied to the CMJ: hands remained on the waist throughout, no additional stop occurred in knee flexion before the jump, the participant did not walk or step after landing, and attention was not distracted. The order of CMJ and DJ trials was randomized using a computergenerated random sequence created in Excel. Each participant was assigned to one of two possible orders (CMJ→DJ or DJ→CMJ) to minimize potential order and fatigue effects. To ensure consistency, participants were instructed to keep their hands on their hips throughout all jumps to minimize arm swing. All jumps were performed barefoot to eliminate variability introduced by footwear and to ensure direct contact with the force plate surface. A rest interval of 60 to 90 seconds was provided between trials to minimize fatigue. All jumps were executed on the force plate, with the IMU and smartphone systems recording simultaneously. Trials were repeated if any technical error occurred, such as sensor displacement, or any jump performance error.
Instrumentation
Force Plate
The reference standard for kinetic measurements was a Kistler 9286BA force plate (Kistler Group, Winterthur, Switzerland), embedded in the laboratory floor and sampling at 1000 Hz. Vertical ground reaction force (vGRF) data were used to derive the performance variables, including jump height, peak concentric force, peak concentric power, and maximum landing force.
IMU and Smartphone-Based System
A wearable inertial measurement unit (IMU; BSNlab Company, Rasht, Iran) sampling at 333 Hz was mounted at the participant’s waist using a custom non-elastic belt. To minimize oscillation and maintain firm contact with the body, the IMU was placed inside a tailored pouch stitched onto the back of the belt. The device incorporated an accelerometer, gyroscope, and magnetometer. A legacy smartphone (LG Optimus Hub E510; LG Electronics, Seoul, South Korea; https://www.gsmarena.com/lg_optimus_hub_e510-4157.php) was used to evaluate a simplified, accelerometer-only configuration. Unlike the IMU, the smartphone did not provide gyroscope or magnetometer data. The smartphone was reported to sample at 160 Hz, and acceleration data were recorded using the Android application Accelerometer Meter, a freely available application designed for accelerometer logging. Because the smartphone was larger than the IMU, mounting it at the waist was considered less practical and potentially less comfortable for participants. It was therefore secured over the greater trochanter using a separate belt. This location was selected because it allowed the phone to be attached securely without interfering with the jumping procedure and was relatively close to the body’s center of mass (COM), although it does not directly measure whole-body COM acceleration. The IMU and smartphone were consequently positioned at different anatomical locations, reflecting practical differences in device size and attachment.
Data Processing
Signal Processing and Event Detection
The force-plate, IMU, and smartphone signals were processed independently. Each system’s signal was analyzed separately to identify the movement events required to calculate its corresponding jump-performance variables. No sample-by-sample waveform comparison or temporal shifting of the signals was performed to achieve inter-device alignment. The purpose of the analysis was to evaluate the validity of performance variables derived from each measurement system against the force-plate reference, rather than to assess inter-device synchronization accuracy. Accordingly, residual timing lag between devices was not evaluated as a separate outcome. A nominal 10-N threshold was used as the event-detection criterion across the processing pipelines. Raw signals were processed using a 20-Hz low-pass Butterworth filter to reduce high-frequency noise and movement artifacts. Movement onset was identified from the derived force-like signal when it crossed the 10-N criterion rather than from a separately recorded physiological event. Similarly, take-off was identified when the force-like signal fell below the threshold. For the force plate, these events were identified from the measured vertical ground reaction force; for the IMU and smartphone, they were identified from the respective sensor-derived force-like signals. Although the same nominal threshold was applied across systems, this does not ensure equivalent event-detection sensitivity. A 10-N threshold represents a small signal when expressed in acceleration-derived terms for a typical adult, and its sensitivity to baseline offsets, measurement noise, filtering, and sampling frequency may differ between the force plate (1000 Hz), IMU (333 Hz), and smartphone (160 Hz). Therefore, the jump-height estimates should be interpreted in the context of the event-detection rule used, and threshold-related error is a plausible contributor to disagreement between measurement systems. Applying a common threshold should not be interpreted as evidence that the threshold has equivalent signal-to-noise characteristics or is equally robust across devices.
Derivation of Force
For the force plate, the measured vertical ground reaction force (vGRF) time series was used to derive the performance variables. The IMU software provided gravity-compensated linear acceleration expressed in the global reference frame. Accordingly, the processed vertical acceleration component was used for subsequent force estimation, thereby avoiding the need for an additional orientation transformation or gravity-removal step in MATLAB. The vertical acceleration signal was expressed according to the adopted coordinate convention before applying the subsequent filtering and force-estimation procedures. This approach allowed the analysis to use the device-processed vertical linear acceleration rather than the raw sensor-axis acceleration. The vertical force estimate was calculated by multiplying the vertical acceleration signal by the participant’s body mass. The resulting signal was smoothed using a second-order Butterworth low-pass filter implemented with forward–backward filtering to avoid phase distortion. The gravitational component was subsequently added to obtain an estimate of the total vertical ground reaction force (GRF):
F̂z(t) = LPF[m · alin,z(t)] + mg
where F̂z(t) denotes the estimated vertical GRF, m is the participant’s body mass, alin,z(t) is the gravity-compensated vertical linear acceleration, and g is the gravitational acceleration (9.81 m/s²). This formulation follows from Newton’s second law, assuming an upward-positive coordinate convention and that the measured vertical acceleration adequately approximates whole-body centre-of-mass acceleration. As the acceleration measured by a body-mounted IMU represents local sensor motion rather than a direct measurement of whole-body centre-of-mass acceleration, the resulting force values were treated as sensor-derived estimates rather than direct measurements of GRF. The purpose of this procedure was to evaluate the agreement of the IMU-derived estimates with the force-plate criterion under the tested acquisition and processing conditions, rather than to assume equivalence between the two measurement methods. This approach is consistent with previous investigations of IMU-based force estimation during vertical jumping, which have examined the relationship between sensor-derived acceleration, body mass, sensor placement, and force-plate measurements (
21).
Derivation of Velocity and Jump Phases
Vertical velocity was derived by numerically integrating absolute vertical acceleration over time using the trapezoidal method. For the countermovement jump (CMJ), initial velocity at movement onset was assumed to be zero. For the drop jump (DJ), the force signal was cropped from a selected time point and reversed in time before integration. Following integration, the resulting velocity signal was returned to its original temporal order. The same general integration procedure was applied to the IMU and smartphone signals to maintain consistency between the portable-device processing pipelines. Reverse-time integration was adopted as an alternative to forward integration for the DJ, for which the initial velocity at the selected integration point was not assumed to be known. This approach relies on a terminal condition and allows the calculated velocity profile to be restored to its original temporal order. Reverse-time integration has been used in previously published jump-biomechanics research (
22). However, the specific criterion used to select the integration time point and the terminal velocity condition are important for reproducibility and should be reported explicitly. The force and velocity curves were subsequently used to identify the eccentric and concentric phases of each jump. The eccentric phase was defined as the interval from the point at which the force-like signal exceeded 10 N until vertical velocity reached zero. The concentric phase extended from the end of the eccentric phase until take-off, identified as the point at which the force-like signal fell below 10 N. These definitions were applied to the signals from the respective measurement systems The following performance metrics were extracted (
9,
23-
27). A representative vertical GRF curve from one subject, recorded simultaneously by force plate, IMU, and smartphone, is shown in
Fig. 1. The following variables were extracted from the vertical ground reaction force (GRF) data: jump height, peak concentric force, peak concentric power, and maximum landing force. Jump height was calculated using the flight-time method, based on the time interval between take-off and landing. Peak concentric force was defined as the maximum vertical force recorded during the concentric phase, whereas peak concentric power was determined as the maximum instantaneous product of vertical force and center-of-mass velocity during the same phase. Maximum landing force was defined as the peak vertical ground reaction force recorded during the landing phase, providing an indicator of the magnitude of impact loading.
Statistical Analysis
To evaluate the concurrent validity and agreement of measurements obtained from the inertial measurement unit (IMU) and smartphone against the reference force plate (FP), several complementary statistical approaches were employed. Absolute agreement and systematic bias were assessed using Bland–Altman analysis. Mean bias, the standard deviation of paired differences, and the 95% limits of agreement (LoA) were calculated for each variable. One-sample t-tests were performed to determine whether the mean differences differed significantly from zero. Proportional bias was examined using linear regression, with the differences between methods (FP − device) as the dependent variable and the corresponding means of the two methods as the independent variable. A statistically significant regression slope (p < 0.05) was interpreted as evidence of proportional bias. Relative association and agreement between measurement systems were evaluated using complementary statistical indices. Intraclass correlation coefficients [ICC(2,1)] were calculated using a two-way random-effects, single-measure, absolute-agreement model. Pearson's correlation coefficients (r) were calculated to assess the strength of linear associations between measurements obtained from each portable device and the force plate. In addition, the standard error of the estimate (SEE) was calculated to quantify the dispersion of observed values around the regression line. The interpretation of agreement statistics was informed by established methodological recommendations (
28,
29). ICC values of 0.75 or higher were considered indicative of at least moderate-to-good agreement, although their interpretation also depended on the corresponding confidence intervals. The width of the Bland–Altman limits of agreement was evaluated in relation to the magnitude of the measured variable and its potential practical implications. Relative measurement errors were also considered when assessing the suitability of the portable devices for individual-level performance evaluation. Statistical significance was set at p < 0.05 for all inferential analyses. All statistical analyses were performed using IBM SPSS Statistics.

Fig. 1. Vertical acceleration derived from the force plate (solid line), the acceleration curve from the inertial measurement unit (IMU; dashed line), and the acceleration curve from the smartphone (dot–dash line).
Results
Descriptive Statistics
Descriptive statistics for the force plate (FP), IMU, and smartphone (SP) during CMJ and DJ in 24 physically active women are presented in
Table 1. Valid observations varied across devices and outcomes due to signal-processing limitations. The IMU yielded higher mean jump-height estimates, particularly during DJ, whereas the smartphone yielded lower estimates. Both portable devices generally underestimated peak concentric force and maximum landing force. The IMU overestimated peak concentric power in both tasks, while the smartphone underestimated it during CMJ and slightly overestimated it during DJ. IMU-derived CMJ height showed considerable variability (SD = 11.01 cm; range = 6–50 cm), with two estimates (50 and 39 cm) substantially exceeding the corresponding FP values (24 and 21 cm). These discrepancies may reflect event-detection errors, although their cause remains unverified.
Agreement and Systematic Bias
Bland–Altman analyses, tests of mean bias, and regression analyses are summarized in
Table 2 and Figs. 2 and 3. Bias was calculated as FP minus the portable-device value; positive values therefore indicate underestimation by the device, and negative values indicate overestimation. LoA describe the range within which most paired differences are expected to fall, assuming the method’s underlying conditions are met. Because signal noise or event-detection problems prevented calculation of some measurements, valid sample sizes varied across comparisons.
Table 1 summarizes available observations for each device and outcome, whereas
Table 2 includes only participants with valid paired measurements; consequently, descriptive means may not equal the paired mean biases.
Table 1. Descriptive statistics, mean (SD), of countermovement and drop jump variables measured by force plate (FP), inertial measurement unit (IMU), and smartphone (SP)
Fig. 2. Bland–Altman plots comparing countermovement jump measurements between the force plate (FP), inertial measurement unit (IMU), and smartphone (SP).
Fig. 3. Bland–Altman plots comparing drop jump measurements between the force plate (FP), inertial measurement unit (IMU), and smartphone (SP).
Table 2. Agreement analysis between the force plate (FP) and portable devices, an inertial measurement unit (IMU) and a smartphone (SP), for countermovement and drop jump metrics, based on Bland–Altman plots, one-sample t-tests, and regression analysis
Note: CMJ: countermovement jump; DJ: drop jump; * Indicates p < 0.05.
Countermovement Jump
For jump height, the IMU showed no significant mean bias (p = 0.564), but the LoA were wide (−18.52 to 16.35 cm), indicating substantial individual-level disagreement. Significant proportional bias was detected (p < 0.001; slope = −1.207), showing that the FP–IMU difference varied with measurement magnitude. The unusually high IMU estimates noted above may have contributed to the variability, but this was not tested. The smartphone underestimated CMJ height (bias = 11.087 cm, p < 0.001; LoA = 5.240 to 16.934 cm). No significant proportional bias was detected for the smartphone comparison (p = 0.657), but this does not establish acceptable individual-level agreement. Both devices underestimated peak concentric force (IMU bias = 1.613 N/kg; smartphone bias = 2.769 N/kg; both p < 0.001). Proportional bias was detected for the IMU (p = 0.019; slope = 0.317) and smartphone (p < 0.001; slope = 1.113), indicating that the FP–device differences varied with the magnitude of the measurements. The slope was steeper for the smartphone comparison. For peak concentric power, the IMU overestimated force-plate values (bias = −8.905 W/kg, p < 0.001; proportional-bias p = 0.031, slope = −0.549). The smartphone underestimated power on average (bias = 5.069 W/kg, p = 0.033) and also showed proportional bias (p = 0.002; slope = −1.188). The negative slope indicates that the FP–smartphone difference became more negative as the mean increased; thus, the average underestimation did not remain constant across the measurement range. Both devices underestimated maximum landing force (IMU bias = 6.127 N/kg; smartphone bias = 14.509 N/kg; both p ≤ 0.002). No significant proportional bias was detected for the IMU (p = 0.411). The smartphone comparison showed a significant regression slope (p < 0.001; slope = 2.00). Smartphone landing-force estimates also had markedly less variability than force-plate measurements. This restricted range and the wide LoA raise concerns about the smartphone’s ability to represent individual differences, but do not establish sensor saturation or clipping as the cause.
Drop Jump
For jump height, the IMU substantially overestimated force-plate values (bias = −13.948 cm, p < 0.001; LoA = −26.750 to −1.145 cm) and showed proportional bias (p < 0.001; slope = −0.898). The smartphone showed a smaller but statistically significant underestimation (bias = 2.468 cm, p < 0.001; LoA = −3.153 to 8.089 cm). Its regression slope was not statistically significant (p = 0.084), but the LoA indicate that individual discrepancies were not negligible. For peak concentric force, the IMU showed a relatively small but significant mean bias (1.708 N/kg, p = 0.015; LoA = −4.548 to 7.964 N/kg), with no significant proportional bias (p = 0.634). The smartphone showed a larger mean bias (5.829 N/kg, p < 0.001) and significant proportional bias (p < 0.001; slope = 0.967), indicating that its difference from the force plate varied with measurement magnitude. For peak concentric power, the IMU overestimated force-plate values (bias = −9.174 W/kg, p < 0.001) and showed proportional bias (p = 0.035; slope = −0.433). The smartphone showed no significant mean bias (−1.654 W/kg, p = 0.610), but significant proportional bias was detected (p = 0.004; slope = −0.571). Thus, a nonsignificant average difference did not indicate consistent agreement across the measurement range. Both devices underestimated maximum landing force (IMU bias = 5.685 N/kg; smartphone bias = 17.468 N/kg; both p ≤ 0.002). No significant proportional bias was detected for the IMU (p = 0.737), whereas the smartphone showed a significant slope (p < 0.001; slope = 0.928). The smartphone also showed restricted variability and wide LoA, indicating limited agreement for landing-force estimation. Overall, Bland–Altman analyses showed that bias and individual-level agreement depended on the device, outcome, and task. A nonsignificant test for proportional bias does not prove that proportional bias is absent, and a nonsignificant mean bias does not establish acceptable LoA. Visual inspection of the Bland–Altman plots (Figs. 2 and 3) reinforces the statistical evidence of device‑ and task‑specific bias. For jump height, the FP–IMU plots for both CMJ and DJ show a clear downward trend, consistent with the significant proportional bias (slopes –1.207 and –0.898, p < 0.001). This pattern indicates that IMU overestimation increases as jump height increases. In contrast, the FP–SP plots display tightly clustered points above the zero line (mean bias: 11.087 cm for CMJ; 2.468 cm for DJ), visually confirming a stable systematic underestimation without proportional bias. For peak concentric force, the FP–SP plots show a distinct upward slope in both CMJ and DJ, matching the significant proportional bias (p < 0.001) and indicating that smartphone underestimation becomes more pronounced at higher force outputs. The FP–IMU plots exhibit a more uniform scatter, particularly in DJ, where no proportional bias was detected (p = 0.634), reflecting relatively stable IMU error across force magnitudes. For peak concentric power, both devices show downward‑sloping scatter in CMJ and DJ. The IMU’s overestimation increases with higher power values, consistent with significant proportional bias (p < 0.05). The smartphone shows a similar downward trend, reflecting underestimation in CMJ and slight overestimation in DJ, but in both tasks the proportional bias (p < 0.05) indicates reduced accuracy at higher power outputs. Finally, for maximum landing force, the FP–IMU plots show a relatively stable distribution around the mean bias line, confirming the absence of proportional error. In contrast, the FP–SP plots, especially in DJ, display a pronounced upward spread, visually reinforcing the significant proportional bias (slope = 0.928, p < 0.001) and highlighting the smartphone’s limited precision at higher impact loads.
Relative Agreement and Precision
The results are shown in
Table 3. For CMJ jump height, both devices had low ICC values (IMU = 0.360;
smartphone = 0.083), despite significant correlations with the force plate (r = 0.612 and 0.573, respectively). For peak concentric force, the IMU showed a higher ICC (0.692) and stronger correlation (r = 0.867) than the smartphone, but its ICC remained below the prespecified threshold of 0.75. ICC values were also low for CMJ peak concentric power and maximum landing force.
Table 3. Intraclass correlation coefficients (ICC2,1), Pearson’s correlation (r), and standard error of estimate (SEE) for jump variables across force plate (FP), inertial measurement unit (IMU), and smartphone (SP).
Note: CI: confidence interval; CMJ: countermovement jump; DJ: drop jump; * Indicates p < 0.05.
These results illustrate that correlation, which describes association, does not necessarily indicate agreement. During DJ, the IMU showed its highest ICC for peak concentric force (ICC = 0.858; 95% CI, 0.651–0.940), with a strong correlation (r = 0.883) and SEE of 0.323 N/kg. This was the only device–outcome combination with an ICC above the prespecified threshold. However, the confidence interval was broad and the LoA ranged from −4.548 to 7.964 N/kg; therefore, this result alone does not establish interchangeability with the force plate. For DJ, the IMU’s ICC for maximum landing force was 0.540, while its ICC for jump height was low (0.150) despite a strong correlation (r = 0.790). Its ICC for peak concentric power was also low. The smartphone had a higher ICC for DJ jump height (0.547) than for the other outcomes, but its significant mean bias and LoA do not support interchangeability. Smartphone ICCs were low for the kinetic outcomes; notably, the smartphone’s correlation for DJ landing force was negative (r = −0.418, p = 0.042), indicating an inverse association rather than meaningful agreement. Overall, agreement depended on the outcome and task. The IMU’s most favorable result was for peak concentric force during DJ, whereas neither device showed consistently high agreement across all variables. The smartphone showed particularly limited agreement for kinetic outcomes. These findings apply to the specific devices, placements, and processing procedures tested and should not be generalized to all IMUs or smartphones.
Discussion
This study evaluated the concurrent validity of a waist-mounted IMU and a greater-trochanter-mounted smartphone accelerometer against a force plate during CMJ and 20-cm DJ. Agreement varied by device, outcome, and task, and neither portable system showed consistently high agreement across all variables. The IMU’s most favorable result was for peak concentric force during DJ; however, jump height, peak concentric power, and maximum landing force generally showed meaningful discrepancies from force-plate measurements. These findings indicate that validity should be evaluated for each outcome and task rather than inferred from a device’s general ability to record movement.
IMU-derived jump height showed substantial disagreement with the force plate, particularly during DJ. During CMJ, the mean bias was small and nonsignificant, but the wide LoA indicated that individual estimates could differ considerably from the reference. Positive and negative errors can offset one another, so a small mean bias does not necessarily indicate good agreement (
28,
30). The significant proportional bias further showed that the FP–IMU difference varied with measurement magnitude. The unusually high CMJ estimates may have contributed to the variability, but this was not examined through sensitivity analysis and their cause remains uncertain. The IMU’s large overestimation of DJ height suggests that the evaluated processing pipeline did not estimate height consistently across tasks. One possible explanation is error in identifying movement events: unlike CMJ, DJ includes an initial aerial phase while the participant steps from the box before landing and performing the reactive jump. If this initial phase is not distinguished from the subsequent jump, estimated flight time may be prolonged. However, the study did not independently compare IMU-detected events with force-plate-defined events, so this explanation remains hypothetical. Soft-tissue movement or belt oscillation could also affect the acceleration signal (
12,
31,
32), but these factors were not measured. Previous studies have reported favorable validity for IMU-based CMJ height estimation using different sensor locations and processing methods. Marković et al. reported excellent agreement using an IMU positioned over the metatarsal region (
31), while Schleitzer et al. evaluated a different sensor configuration and event-detection algorithm (
32). Such findings show that good performance may be achievable with particular configurations, but they do not establish equivalent accuracy for a waist-mounted IMU or during DJ. The present findings therefore concern the specific device configuration and processing pipeline tested, rather than IMU technology in general.
The smartphone also showed limited agreement for jump height. During CMJ, it substantially underestimated force-plate values and had LoA that indicated nontrivial individual error. During DJ, the average discrepancy was smaller but remained statistically significant. The absence of significant proportional bias in the DJ comparison does not establish adequate individual-level accuracy. These results should be distinguished from studies using video-based smartphone applications, such as MyJump, which estimates height from video-derived flight time (
8,
33). Because the measurement principles and event-detection procedures differ, findings for video-based applications cannot be generalized directly to accelerometer-based estimates. Validity depends on the measurement modality, sensor configuration, event-detection method, and processing pipeline. Peak concentric force was the most promising outcome for the IMU, particularly during DJ. Its ICC exceeded the prespecified threshold (0.858), and its correlation with the force plate was strong. However, the ICC confidence interval was relatively wide, and the LoA ranged from −4.548 to 7.964 N/kg. Whether this error is acceptable depends on the intended application and the magnitude of change or difference that must be detected. The result supports further investigation of IMU-derived peak concentric force during DJ but does not establish interchangeability for individual assessment. Agreement for IMU-derived CMJ peak concentric force was lower, and smartphone ICC values for peak concentric force were low in both tasks. Previous research has likewise shown that the accuracy of IMU-based force estimation can vary with sensor location and the method used to estimate ground-reaction force (
14,
34).
The measurement principles of the systems are also important. The force plate directly measures external ground-reaction force, whereas the portable systems estimate net force from local sensor acceleration and body mass. Local segment acceleration is not equivalent by definition to whole-body COM acceleration or external GRF; the estimate depends on the reference frame, gravity correction, sensor orientation, and processing method (
12,
14). Therefore, discrepancies may reflect both the measurement principles and the procedures used to derive each outcome. Because device type, placement, sampling frequency, and sensor configuration differed simultaneously, the more favorable IMU result cannot be attributed to any single factor. Studies that control these factors independently are needed. Neither portable device showed consistently high agreement for peak concentric power. Power estimation depends on both force and velocity estimates, so errors in either component can affect the final value. Velocity was obtained by integrating acceleration, which can be sensitive to baseline offsets, noise, event selection, and accumulated integration error (
12,
14). However, the present results do not establish that integration drift caused the discrepancies: residual velocity and end-of-trial integration error were not assessed, and device-derived velocity was not compared with an independent reference. The relative contributions of force estimation, velocity estimation, phase segmentation, and integration therefore remain unknown. Future studies should validate velocity estimates directly and examine how integration procedures and event definitions affect power calculations. Both portable devices underestimated maximum landing force, with greater average underestimation by the smartphone. The IMU showed no significant evidence of proportional bias in either task, but its wide LoA indicated substantial individual-level error. Smartphone estimates had restricted variability relative to the force plate and significant regression slopes in both tasks. This pattern raises concerns about the smartphone’s ability to represent the range of landing-force values, but does not demonstrate sensor saturation or clipping; these explanations require inspection of the sensor’s operating range and raw signals.
Signal processing may also have affected landing-force estimates. The 20-Hz low-pass filter may have attenuated sharp peaks, depending on the signal characteristics and filter implementation. However, alternative cutoffs were not tested, and force-plate signals were not reprocessed using an equivalent pipeline. The contribution of filtering to the observed discrepancies therefore remains uncertain. This limitation concerns the processing pipeline evaluated and should not automatically be attributed to the sensor hardware. Future work should compare processing procedures under controlled conditions and inspect raw signals before assigning discrepancies to device characteristics. Sampling frequency alone is unlikely to explain the observed discrepancies. The smartphone’s sampling interval was much shorter than the flight-time discrepancy observed for the IMU during DJ, so sampling frequency alone does not adequately explain its magnitude. The sampling rates were also sufficient to represent the frequency range retained by the 20-Hz low-pass filter. These observations do not rule out all sampling-related effects, but the present design cannot establish that sampling frequency caused the errors. Because device type, placement, sensor configuration, sampling frequency, and processing procedures were not independently controlled, causal comparisons between the IMU and smartphone are not possible. The practical implications should be interpreted cautiously. The IMU’s relatively favorable agreement for peak concentric force during DJ warrants further investigation, but this study evaluated agreement rather than test–retest reliability or responsiveness. Averaging repeated trials does not establish whether a device can consistently measure an individual’s performance across sessions or detect change during training or rehabilitation. The findings therefore do not support recommendations for longitudinal monitoring or individual progress tracking. Such applications require dedicated assessment of repeatability, measurement error, and responsiveness, with acceptable error thresholds defined in advance.
Several limitations should be considered when interpreting these findings. First, the sample comprised 24 physically active young females, which limits the generalizability of the findings to other populations. Although a supplementary precision assessment was conducted for ICC estimation, no a priori sample-size calculation was performed to establish the required precision of all agreement estimates, particularly the Bland–Altman limits of agreement (LoA). Moreover, this assessment depended on the assumed ICC and the target confidence-interval width. Future studies should recruit larger and more diverse samples and determine sample sizes based on prespecified outcomes and desired levels of precision. Second, device type, sensor configuration, sampling frequency, and anatomical placement were confounded. The waist-mounted multisensor IMU sampled at 333 Hz, whereas the greater-trochanter-mounted legacy smartphone sampled at 160 Hz and provided only a single vertical-axis acceleration channel, without concurrent gyroscope or magnetometer data. The smartphone was selected as a low-cost, minimalist comparator rather than as a representative of contemporary smartphones. Differences in mounting location may also have introduced variability associated with rotational movement and soft-tissue artifact. Consequently, the independent contributions of these factors to the observed measurement discrepancies could not be determined. Future studies should compare co-located sensors under standardized acquisition and processing conditions and include contemporary smartphones. Third, reliability and responsiveness were not assessed because the three trials per task were aggregated rather than analyzed to evaluate trial-to-trial or test–retest consistency. In addition, only a 20-cm drop height was investigated, limiting the applicability of the findings to other drop heights and jump protocols. Future research should assess reliability and responsiveness separately and examine a broader range of jump and landing tasks. Fourth, measurement discrepancies may have been influenced by methodological and signal-processing factors. Sensor calibration procedures and operating ranges were insufficiently characterized to determine whether calibration errors, saturation, or clipping occurred. Jump height was derived from flight time using threshold-based event detection; therefore, estimates may have been sensitive to errors in identifying take-off and landing, particularly in noisy signals. No sensor-orientation correction was applied, sensitivity to alternative low-pass filter cutoffs was not examined, and force-plate signals were not processed using an identical filtering pipeline. The individual contributions of these factors to the observed discrepancies therefore remain uncertain. Future studies should document calibration procedures and sensor operating ranges, validate event detection against reference events, evaluate orientation correction where appropriate, and compare alternative processing pipelines using synchronized reference measurements. Finally, multiple outcomes were examined across devices and jump tasks, increasing the possibility of chance findings. The results should therefore be interpreted in the context of the overall pattern of agreement rather than statistical significance alone. Future studies should prespecify primary outcomes, justify their methods for controlling multiple comparisons, and report confidence intervals alongside point estimates. In addition, signal noise and event-detection failures resulted in varying numbers of valid observations across analyses. Descriptive statistics in
Table 1 were based on the available observations for each device and outcome, whereas the Bland–Altman analyses in
Table 2 included only participants with valid paired measurements. Consequently, descriptive means may not correspond exactly to the paired mean biases. Future studies should report the number of valid paired observations for each comparison and investigate the causes and implications of missing measurements.
Conclusion
Neither tested portable system provided consistently interchangeable measurements with the force plate across CMJ and 20-cm DJ outcomes. The waist-mounted IMU showed its most favorable agreement for peak concentric force during DJ, but the observed LoA indicate that interchangeability for individual assessment has not been established. The tested smartphone showed limited agreement, particularly for kinetic outcomes. These findings emphasize that each device configuration and processing pipeline must be validated for the specific outcome and task before its measurements are used as substitutes for force-plate data. Further work should prioritize standardized sensor comparisons, direct validation of movement-event detection, larger and more diverse samples, and dedicated assessments of reliability and responsiveness.
AcknowledgementThe authors express their sincere gratitude to the staff of the Movement Disorders and Gait Analysis Laboratory in the Department of Physiotherapy, Faculty of Medical Sciences, Tarbiat Modares University, as well as to the BSNlab staff, for their valuable support and technical assistance.
Ethical Considerations
Compliance with ethical guidelines
This study was approved by the Ethics Committee of Tarbiat Modares University, Tehran, Iran (approval code: IR.MODARES.REC.1400.107), and conducted in accordance with the Declaration of Helsinki. Written informed consent was obtained from all participants prior to participation.