Volume 12, Issue 4 (2-2027)                   J Sport Biomech 2027, 12(4): 1004-1040 | Back to browse issues page


XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Nazari M, Boozari S, Mohamadi S, Farjad Pezeshk A, Torkaman G. Concurrent Validity of an Inertial Measurement Unit and Smartphone Accelerometer Against a Force Plate During Countermovement and Drop Jumps in Active Women. , J Sport Biomech. 2027; 12 (4) :1004-1040
URL: http://biomechanics.iauh.ac.ir/article-1-544-en.html
1- Department of Physiotherapy, Faculty of Medical Sciences, Tarbiat Modares University, Tehran, Iran.
2- Physiotherapy Department, Neuromusculoskeletal Rehabilitation Research Center, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran.
3- Department of Sport Sciences, Faculty of Physical Education and Sport Sciences, University of Birjand, Birjand, Iran.
Abstract:   (31 Views)
Objective This study evaluated the concurrent validity of an inertial measurement unit (IMU) and a smartphone accelerometer against a force plate during countermovement (CMJ) and drop jumps (DJ) in recreationally active women.
Methods Twenty-four recreationally active women performed three CMJ and three 20-cm DJ trials while signals from all three devices were recorded simultaneously. The mean of three valid trials was analyzed. Absolute agreement and proportional bias were assessed using Bland–Altman analysis and linear regression, respectively. Relative validity was evaluated using intraclass correlation coefficients (ICC), Pearson’s correlation, and the standard error of estimate (SEE).
Results The IMU showed little mean bias but wide limits of agreement for CMJ height and overestimated DJ height. The smartphone underestimated jump height in both tasks. The highest agreement was observed for IMU-derived peak concentric force during DJ (ICC = 0.858), although the limits of agreement remained wide. Agreement for peak concentric power and landing force was generally limited, while smartphone-derived kinetic variables showed poor agreement with the force plate.
Conclusion Neither device provided consistently interchangeable measurements with the force plate. The IMU showed more favorable agreement for peak concentric force during DJ, but further validation is required before individual-level assessment. These findings are limited to the tested devices, sensor placements, and processing procedures.
Full-Text [PDF 2189 kb]   (6 Downloads) |   |   Full-Text (HTML)  (10 Views)  
Type of Study: Research | Subject: General
Received: 2026/07/11 | Accepted: 2026/11/16 | Published: 2026/11/29

References
1. Claudino JG, Cronin J, Mezêncio B, McMaster DT, McGuigan M, Tricoli V, et al. The countermovement jump to monitor neuromuscular status: a meta-analysis. Journal of Science and Medicine in Sport. 2017;20(4):397-402. [DOI:10.1016/j.jsams.2016.08.011]
2. Hamill J, Knutzen KM. Biomechanical basis of human movement. 3rd ed. Philadelphia (PA): Lippincott Williams & Wilkins; 2009.
3. Linthorne NP. Analysis of standing vertical jumps using a force platform. American Journal of Physics. 2001;69(11):1198-1204. [DOI:10.1119/1.1397460]
4. Arlotti JS, Carroll WO, Afifi Y, Talegaonkar P, Albuquerque L, Ball JE, et al. Benefits of IMU-based wearables in sports medicine: narrative review. International Journal of Kinesiology and Sports Science. 2022;10(1):36-43. [DOI:10.7575/aiac.ijkss.v.10n.1p.36]
5. Camomilla V, Bergamini E, Fantozzi S, Vannozzi G. Trends supporting the in-field use of wearable inertial sensors for sport performance evaluation: a systematic review. Sensors. 2018;18(3):873. [DOI:10.3390/s18030873]
6. Clemente F, Badicu G, Hasan UC, Akyildiz Z, Pino-Ortega J, Silva R, et al. Validity and reliability of inertial measurement units for jump height estimations: a systematic review. Human Movement. 2022;23(4):1-20. [DOI:10.5114/hm.2023.111548]
7. da Rocha EF, Orssatto LBR, Diefenthaeler F, Dellagrana RA. Jump height with smartphone apps-reliability and agreement with standard methods: a systematic review with meta-analysis. Strength and Conditioning Journal. 2026;48(1):65-77. [DOI:10.1519/SSC.0000000000000918]
8. Gençoğlu C, Ulupınar S, Özbay S, Turan M, Savaş BÇ, Asan S, et al. Validity and reliability of My Jump app to assess vertical jump performance: a meta-analytic review. Scientific Reports. 2023;13(1):20137. [DOI:10.1038/s41598-023-46935-x]
9. Haj-Lotfalian M. Validation of a low-cost inertial sensor for estimating barbell velocity during deadlift concentric phase. Journal of Sport Biomechanics. 2026;12(1):20-34. [DOI:10.61882/JSportBiomech.12.1.20]
10. Macadam P, Cronin J, Neville J, Diewald S. Quantification of the validity and reliability of sprint performance metrics computed using inertial sensors: a systematic review. Gait & Posture. 2019;73:26-38. [DOI:10.1016/j.gaitpost.2019.07.123]
11. Nazari M, Boozari S, Torkaman G, Sanjari MA. Validity and reliability of the accelerometer for assessing jump performance variables: review study. International Journal of Musculoskeletal Pain Prevention. 2024;9(4):1121-1132.
12. Rantalainen T, Finni T, Walker S. Jump height from inertial recordings: a tutorial for a sports scientist. Scandinavian Journal of Medicine & Science in Sports. 2020;30(1):38-45. [DOI:10.1111/sms.13546]
13. Haff GG, Ruben R, Saffel H, McCrory JL, Cormie P, Sands WA, et al. Reliability of accelerometer based performance measurements during countermovement vertical jumps and the influence of sampling frequency. Journal of Strength and Conditioning Research. 2011;25:S92. [DOI:10.1097/01.JSC.0000395725.37612.48]
14. Kerns JA, Zwart AS, Perez PS, Gurchiek RD, McBride JM. Effect of IMU location on estimation of vertical ground reaction force during jumping. Frontiers in Bioengineering and Biotechnology. 2023;11:1112866. [DOI:10.3389/fbioe.2023.1112866]
15. Ziebart C, Giangregorio LM, Gibbs JC, Levine IC, Tung J, Laing AC. Measurement of peak impact loads differ between accelerometers-effects of system operating range and sampling rate. Journal of Biomechanics. 2017;58:222-226. [DOI:10.1016/j.jbiomech.2017.04.022]
16. Bishop C, Turner A, Jordan M, Harry J, Loturco I, Lake J, et al. A framework to guide practitioners for selecting metrics during the countermovement and drop jump tests. Strength and Conditioning Journal. 2022;44(4):95-103. [DOI:10.1519/SSC.0000000000000677]
17. Young WB, Pryor JF, Wilson GJ. Effect of instructions on characteristics of countermovement and drop jump performance. Journal of Strength and Conditioning Research. 1995;9(4):232-236. [DOI:10.1519/1533-4287(1995)0092.3.CO;2]
18. Muyor JM, Granero-Gil P, Pino-Ortega J. Reliability and validity of a new accelerometer (Wimu) system for measuring velocity during resistance exercises. Proceedings of the Institution of Mechanical Engineers, Part P: Journal of Sports Engineering and Technology. 2018;232(3):218-224. [DOI:10.1177/1754337117731700]
19. Patterson JA, Amick RZ, Pandya PD, Hakansson N, Jorgensen MJ. Comparison of a mobile technology application with the balance error scoring system. International Journal of Athletic Therapy and Training. 2014;19(3):4-7. [DOI:10.1123/ijatt.2013-0094]
20. Tran J, Netto K, Aisbett B, Gastin P. Validation of accelerometer data for measuring impacts during jumping and landing tasks. In: Proceedings of the 28th International Conference on Biomechanics in Sports; 2010; Marquette, Michigan, USA. p. 148-151.
21. Miranda-Oliveira P, Branco M, Fernandes O. Accuracy of inertial measurement units when applied to the countermovement jump of track and field athletes. Sensors. 2022;22(19):7186. [DOI:10.3390/s22197186]
22. Barker L, Loosbrock A, Spry E, Ciccone A, Grindstaff T. Velocity-specific relationships among eccentric and concentric force velocity profiles and jumping performance. International Journal of Strength and Conditioning. 2024;4(1):1-9. [DOI:10.47206/ijsc.v4i1.264]
23. Boozari S, Sanjari MA, Amiri A, Takamjani IE. Effect of gastrocnemius kinesio taping on countermovement jump performance and vertical stiffness following muscle fatigue. Journal of Sport Rehabilitation. 2018;27(4):306-311. [DOI:10.1123/jsr.2017-0009]
24. Helland C, Midttun M, Saeland F, Haugvad L, Olstad DS, Solberg PA, et al. A strength-oriented exercise session required more recovery time than a power-oriented exercise session with equal work. PeerJ. 2020;8:e10044. [DOI:10.7717/peerj.10044]
25. Ali-Hassan MF, Abdulkareem OW, Ali LS. Effects of high-intensity plyometric training on force-time characteristics during volleyball spike and block jumps. Journal of Sport Biomechanics. 2027;12(4):732-755.
26. Nazari M, Boozari S, Sanjari MA, Torkaman G. The effect of whole-body vibration with medium and high frequencies in static and dynamic squats on jump performance in healthy non-athlete females. Sport Sciences for Health. 2024;20(4):1455-1464. [DOI:10.1007/s11332-024-01225-5]
27. Nickpey Z, Boozari S, Farjad Pezeshk A. Effects of kinesio tape on countermovement jump kinetic variables in physically active females with flat feet before and after fatigue: a randomized controlled trial. BMC Sports Science, Medicine and Rehabilitation. 2025;17(1):309. [DOI:10.1186/s13102-025-01355-4]
28. Atkinson G, Nevill AM. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Medicine. 1998;26(4):217-238. [DOI:10.2165/00007256-199826040-00002]
29. Hopkins WG. Measures of reliability in sports medicine and science. Sports Medicine. 2000;30(1):1-15. [DOI:10.2165/00007256-200030010-00001]
30. Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. International Journal of Nursing Studies. 2010;47(8):931-936. [DOI:10.1016/j.ijnurstu.2009.10.001]
31. Marković S, Dopsaj M, Tomažič S, Kos A, Nedeljković A, Umek A. Can IMU provide an accurate vertical jump height estimate? Applied Sciences. 2021;11(24):12025. [DOI:10.3390/app112412025]
32. Schleitzer S, Wirtz S, Julian R, Eils E. Development and evaluation of an inertial measurement unit (IMU) system for jump detection and jump height estimation in beach volleyball. German Journal of Exercise and Sport Research. 2022;52(2):228-236. [DOI:10.1007/s12662-022-00822-1]
33. Stanton R, Wintour SA, Kean CO. Validity and intra-rater reliability of MyJump app on iPhone 6s in jump performance. Journal of Science and Medicine in Sport. 2017;20(5):518-523. [DOI:10.1016/j.jsams.2016.09.016]
34. Cabarkapa DV, Cabarkapa D, Philipp NM, Fry AC. Impact of the anatomical accelerometer placement on vertical jump performance characteristics. Sports. 2023;11(4):92. [DOI:10.3390/sports11040092]

Rights and permissions